Modeling
Equipment and spreadsheets in the C3MR example
Start at NG-1 and follow the material flow through the equipment. Check energy transfer and outlet pressure in PROP-C1, then compare the hot and cold composite curves in PHX1. On the flowsheet, SET-1 links a source property to a target setpoint. In RCY-1, compare the current error with its tolerance. Open MSHEX before the flowsheet calculation and MR_COMPR afterwards to follow data exchange between cells and equipment.
Equipment and spreadsheet links in the worked example · Expander calculation, ΔT and a PHX1 chart marker
Material Flow Calculation
Material flow is the basic object for technological modeling. It represents substance that moves between equipment.
To correctly calculate the flow, it is necessary to set the initial data - specification, flow rate and component composition. The process of setting initial parameters is carried out in the window of material flow properties.

In the “Conditions” sub tab, the user sets the thermobaric parameters and the flow rate. A total of 5 types of flow specifications:
-
temperature - pressure
-
pressure - enthalpy
-
pressure - entropy
-
pressure - vapor fraction
-
temperature - vapor fraction
The specification is automatically selected depending on the combination of parameters for which the user has set a value.
On the “Composition” sub tab the component composition of the material flow is set.

To initially enter or edit a composition, click on the “Edit” button. As a result the following window will open:

The cells in the second column of the table become available for entering values. In addition, the composition input window has a number of functions:
-
button “Clear” - clears all previously entered values in the table
-
button “Allocate” - distributes fractions evenly over all components
-
button “Normalize” - normalizes the composition to 1 in proportion to the previously entered fractions.
-
Composition basis - allows you to select the basis (mole/mass fractions, mole/mass costs) for entering the component composition.
After entering the data, the flow is ready for calculation.
Valve Calculation
The valve is designed to simulate the pressure change in a material flow in an isoentropic process.
-
the equipment has connections to the inlet and outlet material flows.
-
the inlet material flow has been calculated or fully predetermined
-
equipment specification is defined and its value is set
In the “Parameters” sub tab of the valve properties window, the parameter to be specified is set.

Accordingly, two operating modes of the valve are supported:
-
pressure drop
-
outlet pressure
The “Composition”, “Properties” and “Compositions” sub tabs display relevant information on incoming and outgoing material flows and are common to all types of equipment.
- "Conditions” sub tab

- "Properties" sub tab

- "Compositions" sub tab

Separator Calculation
The separator is designed to separate the incoming material flow into vapor and liquid phases.
Three conditions must be met to calculate the equipment:
-
The equipment has connections to the inlet and outlet material flows and the energy flow
-
the input material flow is calculated or fully predetermined
-
equipment specification is defined and its value is set.
On the “Parameters” sub tab you can enter the equipment parameters. Input of differential pressure at the separator inlet is supported.

The “Conditions”, “Properties” and “Composition” sub tabs are typical for all types of equipment and contain information about properties and parameters of incoming and outgoing material flows.
Heater/Cooler Calculation
The heater and cooler are designed to heat or cool the material flow respectively.
Three conditions must be met to calculate the equipment:
-
the equipment has connections to the material flows at the inlet and outlet and the energy flow
-
the input material flow is calculated or fully predetermined
-
equipment specification is defined and its value is set.
On the “Parameters” sub tab you can enter the equipment parameters.
- "Parameters” sub tab for the heater

- "Parameters" sub tab for the cooler

The parameters “Delta P” and “Efficiency” are optional and are always available for editing. The rest of the parameters are specifications, where the user has to set manually one of the parameters, and the rest of the properties are not available for editing and are calculated.
The sub tabs “Conditions”, “Properties” and “Composition” are typical for all types of equipment and contain information about properties and parameters of incoming and outgoing material flows.